You are buying one Nokia 7210 SAS-Sx 22F2C4SFP+ 1RU Switch 3HE10493ABRB01.
What is included:- Nokia 7210 SAS-Sx 22F2C4SFP+ chassis.- Front rack mount ears and screws (check photos).- One DC power supply.
Condition:- Pulled from the lab/demonstration environment.
- The DC power supply and all interfaces confirmed working.- Overall look is 9/10. Check photos.- Front rack mounts and screws are included.- Power cables are NOT included.- Non-original packaging.- The software is installed on the internal storage (cf1:). No additional/external cf card is required.- Login/pass admin/admin
The switch was acquired few years back and since then it was a part of the lab setup to practice and work on Nokia certs (NRS/SRA).
A:NS2033C2896# /show Name : NS2033C2896
Type : 7210 SAS-Sx 22F2C4SFP+-1
Location :
Coordinates :
CLLI code :
Number of slots : 2
Number of ports : 28
System LED state : Green
Over Temperature state : OK
Base MAC address : 8c:83:df:88:1d:dd
Number of MAC addresses : 512
Hardware Data
Part number : 3HE10493ABRB01
CLEI code : INM3T10ARA
Serial number : NS2033C2896
Manufacture date : 08142020
Manufacturing deviations : (Not Specified)
Manufacturing assembly number :
Temperature : 65C
Time of last boot : 2000/01/01 00:54:46
Current alarm state : alarm cleared
Firmware revision status : Information Number of fan trays : 1
Number of fans : 3 Fan tray number : 1
Speed : half speed
Status : Supply Information
Number of power supplies : 2 Power supply number : 1
Configured power supply type : dc (-48V)
Status : up
DC power : within range
Input power : within range
Output power : within range
Hardware Data
Part number : 3HE10499AARA01
CLEI code : IPUPARBUAA
Serial number : NS2033B0164 Power supply number : 2
Configured power supply type : none
Status : not equipped
Hardware Data
Part number :
CLEI code :
Serial number /show version
TiMOS-B-21.3.R2 both/hops Nokia SAS-Sx 22F2C4SFP+ 7210 Copyright (c) 2000-2021 Nokia.
All rights reserved. All use subject to applicable license agreements.
Built on Wed Jul 7 15:07:16 IST 2021 by sasbuild in show on Slot Admin Link Port Cfg Oper LAG/ Port Port Port C/QS/S/XFP/
Id State State MTU MTU Bndl Mode Encp Type Up No Down 9212 9212 - netw null xcme COMBO
1/1/2 Up No Down 9212 9212 - netw null xcme COMBO
1/1/3 Up No Down 9212 9212 - netw null xcme
1/1/4 Up No Down 9212 9212 - netw null xcme
1/1/5 Up No Down 9212 9212 - netw null xcme
1/1/6 Up No Down 9212 9212 - netw null xcme
1/1/7 Up No Down 9212 9212 - netw null xcme
1/1/8 Up No Down 9212 9212 - netw null xcme
1/1/9 Up No Down 9212 9212 - netw null xcme
1/1/10 Up No Down 9212 9212 - netw null xcme
1/1/11 Up No Down 9212 9212 - netw null xcme
1/1/12 Up No Down 9212 9212 - netw null xcme
1/1/13 Up No Down 9212 9212 - netw null xcme
1/1/14 Up No Down 9212 9212 - netw null xcme
1/1/15 Up No Down 9212 9212 - netw null xcme
1/1/16 Up No Down 9212 9212 - netw null xcme
1/1/17 Up No Down 9212 9212 - netw null xcme
1/1/18 Up No Down 9212 9212 - netw null xcme
1/1/19 Up No Down 9212 9212 - netw null xcme
1/1/20 Up No Down 9212 9212 - netw null xcme
1/1/21 Up No Down 9212 9212 - netw null xcme
1/1/22 Up No Down 9212 9212 - netw null xcme
1/1/23 Up No Down 9212 9212 - netw null xcme
1/1/24 Up No Down 9212 9212 - netw null xcme
1/1/25 Up No Down 9212 9212 - netw null vspeede
1/1/26 Up No Down 9212 9212 - netw null vspeede
1/1/27 Up No Down 9212 9212 - netw null vspeede
1/1/28 Up Yes Up 9212 9212 - netw null vspeede on Slot Admin Link Port Cfg Oper LAG/ Port Port Port C/QS/S/XFP/
Id State State MTU MTU Bndl Mode Encp Type Up No Down 1514 1514 - netw null