UBB Store

Commscope CS34P 23/4P Cat6 F/UTP WebTrak Plenum CMP Network Cable White 100'FT +
When you click on links to various merchants on this site and make a purchase, this can result in this site earning a commission. Affiliate programs and affiliations include, but are not limited to, the eBay Partner Network.
Commscope CS34P 23/4P Cat6 F/UTP WebTrak Plenum CMP Network Cable White 100'FT +
Price: US $55.00
One WHITE ShieldPlenumXX-FT with no Attached on the end of Cable.SpecificationsProduct ClassificationRegional AvailabilityNorth AmericaPortfolioUniprise®Product TypeTwisted pair cableGeneral SpecificationsProduct NumberCS34PANSI/TIA Category6Cable Component TypeHorizontalCable TypeF/UTP (shielded)Conductor Type, singlesSolidConductors, quantity8Drain Wire TypeSolidJacket ColorBlueNoteAll electrical transmission tests include swept frequency measurementsPairs, quantity4Separator TypeIsolatorTransmission StandardsANSI/TIA-568.2-D | CENELEC EN 50288-6-1 | ISO/IEC 11801 Class EDimensionsCable Lengthxx'FTDiameter Over Insulated Conductor1.080 mm | 0.0425 inDiameter Over Jacket, nominal6.934 mm | 0.273 inJacket Thickness0.457 mm | 0.018 inConductor Gauge, singles23 AWGDrain Wire Gauge
Cross Section DrawingClick on image to enlarge.Electrical SpecificationsCharacteristic Impedance100 ohmdc Resistance Unbalance, maximum5 %dc Resistance, maximum8 ohms/100 m | 2.438 ohms/100 ftDelay Skew, maximum45 nsDielectric Strength, minimum1500 Vac | 2500 VdcMutual Capacitance at Frequency5.6 nF/100 m @ 1 kHzNominal Velocity of Propagation (NVP)71 %Operating Frequency, maximum250 MHzOperating Voltage, maximum80 VRemote PoweringFully complies with the recommendations set forth by IEEE 802.3bt (Type 4) for the safe delivery of power over LAN cable when installed according to ISO/IEC 14763-2, CENELEC EN 50174-1, CENELEC EN 50174-2 or TIA TSB-184-ASafety Voltage Rating300 VElectrical Cable PerformanceCSCommScopeStdRefers to the standard value listed under Transmission Standards in the Electrical Specifications aboveTypTypicalILInsertion Loss (dB/100m)NEXTNear End Crosstalk (dB/100m)ACRAttenuation to Crosstalk Ratio (dB/100m))PSNEXTPower Sum Near End Crosstalk (db/100m)PSACRPower Sum Attenuation to Crosstalk Ratio (dB/100m)ACRFAttenuation to Crosstalk Ratio - Far End (dB/100m)PSACRFInsertion Loss (dB/100m)RLReturn Loss (dB)FrequencyIL, STDIL, TYPNEXT, STDNEXT, TYPACR, STDACR, TYPPSNEXT, STDPSNEXT, TYPPSACR, STDPSACR, TYPACRF, STDACRF, TYPPSACRF, STDPSACRF, TYPRL, STDRL, TYP1.00 MHz36.344.78.442.86.538.536.219.0500.00 SpecificationsConductor MaterialBare copperDrain Wire MaterialTinned copperInsulation MaterialFEPJacket MaterialPVCSeparator MaterialFEPShield (Tape) MaterialAluminum/PolyesterMechanical SpecificationsPulling Tension, maximum
Environmental SpecificationsInstallation temperature0 °C to +60 °C (+32 °F to +140 °F)Operating Temperature-20 °C to +60 °C (-4 °F to +140 °F)Environmental SpacePlenumFlame Test MethodCMP/FT6 | NEC Article 800 | NFPA 262 | UL 444 | UL 910Smoke Test MethodCMP/FT6Packaging and WeightsCable weight
Regulatory 9001:2015Designed, manufactured and/or distributed under this quality management systemROHSCompliantCHINA-ROHSBelow maximum concentration valueREACH-SVHCCompliant as per SVHC revision on style="font-family: Arial; font-size: 14pt;">



Buy Now