Love Manufacturer: Tripp Lite
Model: Tripp Lite SmartOnline UPS 3000VA 2700W, RM, 2U, 30A, 120V, New Batteries, Refurbished UPS
Condition: New batteries, refurbished UPS
Part Number: SU3000RTXL2U
Maximum output: 2700W / 3000VA
Typical backup time at half load: 13.8 minutes (1350 Watts)
Typical backup time at full load: 4.8 minutes (2700 Watts)
Warranty: 1 year full replacement warranty
Tripp Lite SmartOnline 3000VA 2700W Tower120V SU3000RTXL2UManual
SU3000RTXL2U - Tripp Lite SmartOnline 3000VASpecifications:
Input:
Rated input current (Maximum Load)
24A maximum
Nominal Input Voltage(s) Supported
120V AC
UPS Input Connection Type
NEMA L5-30P
Recommended Electrical Service
30A 120V
Input Phase
Single-Phase
Input Cord Length (ft.)
10
Input Cord Length (m)
3.05
Output:
Output Volt Amp Capacity (VA)
3000
Output kVA Capacity (kVA)
3
Output Watt Capacity (Watts)
2700
Output kW Capacity (kW)
2.70
Power Factor
0.9
Crest Factor
3:1
Nominal Voltage Details
120V default
Frequency Compatibility
50 / 60 Hz
Frequency Compatibility Details
Accepts 40 to 70Hz input frequency. Output frequency matches input nominal on startup, defaults to 60 Hz on coldstart. Frequency conversion from 60 to 50 Hz -or- 50 to 60 Hz supported. Output capacity de-rates to 70% of
normal levels during frequency conversion operation.
Output Voltage Regulation (Line Mode)
+/- 2%
Output Voltage Regulation (Economy Line Mode)
+/- 10%
Output Voltage Regulation (Battery Mode)
+/- 2%
Load Management Receptacles
Two switchable three-outlet load banks
Output Circuit Breakers
20A (x2) - each breaker protects 3 5-15/20R outlets, L5-30R outlet is un-breakered
Output AC Waveform (AC Mode)
Pure Sine wave
Output AC Waveform (Battery Mode)
Pure Sine wave
Output Capacity Details
INVERTER SHORT-CIRCUIT PROTECTION: Inverter short-circuit protection is electrically protected; OVERLOAD
CAPACITY: Supports inverter operation up to 105% load continuously, 125% for 30 seconds, 150% for 10 seconds
and >150% for 0.5 seconds before switching to BYPASS (when bypass input voltage and frequency are WITHIN
bypass limits of 120V ±10%) or SHUTDOWN (when bypass input voltage or frequency are OUTSIDE bypass limits
of 120V ±10%).
Nominal Output Voltage(s) Supported
100V; 110V; 115V; 120V; 127V
Output Receptacles
(6) NEMA 5-20R
(1) NEMA L5-30R
Individually Controllable Load Banks
Yes
Battery:
Full Load Runtime (min.)
4.8 min. (2700w)
Half Load Runtime (min.)
13.8 min. (1350w)
Expandable Battery Runtime
Supports extended runtime with optional external battery packs
External Battery Pack Compatibility
BP72V15-2U (limit 1); BP72V28RT-3U (multi-pack compatible); BP72V18-2US (multi-pack compatible)
DC System Voltage (VDC)
72
Battery Recharge Rate (Included Batteries)
Less than 8.1 hours from 10% to 90% (typical, full load discharge)
Internal UPS Replacement Battery
Cartridge
See RBC selector guide (replacement battery part number is also labeled on the internal battery door)
Battery Access
Front panel battery access door
Battery Replacement Description
Hot-swappable, user replaceable batteries
Expandable Runtime
Yes
Voltage Regulation:
Voltage Regulation Description
Online, double-conversion power conditioning
Overvoltage Correction
ONLINE MODE: 2% output voltage regulation during overvoltages to 150
Undervoltage Correction
2% output voltage regulation during undervoltages to 80V (66-100% load)
Severe Undervoltage Correction
2% output voltage regulation during undervoltages to 70V (33-66% load) or 60V (under 33% load)
User Interface, Alerts & Controls:
Switches
2 Switches control off/on power status and alarm-cancel/self-test operation
Alarm Cancel Operation
Power-fail alarm can be silenced using alarm-cancel switch
Audible Alarm
Audible alarm indicates power failure, low battery, overload, replace battery and EPO operation
LED Indicators
14 LEDs indicate line power, online mode, economy/bypass mode, on-battery, overload, battery low, replace battery and fault status information; 4-LED meter displays load and battery charge levels; LED panel rotates for viewing in rack/tower formats
Surge / Noise Suppression:
UPS AC Suppression Joule Rating
504
EMI / RFI AC Noise Suppression
Yes
AC Suppression Response Time
Instantaneous
Physical:
Cooling Method
Fan
Included Mounting Accessory
Description
Includes 4 post rackmount installation accessories
Installation Form Factors Supported
with Optional Accessories
2 post rackmount ( 2POSTRMKITWM ); Tower ( 2-9USTAND )
Minimum Required Rack Depth with
External Battery Pack (cm)
77
Minimum Required Rack Depth with
External Battery Pack (in.)
30.25
Minimum Required Rack Depth
without External Battery Pack (cm)
74
Minimum Required Rack Depth
without External Battery Pack (in.)
29.25
Primary Form Factor
Rackmount
Primary UPS Depth (mm)
616
Primary UPS Height (mm)
88
Primary UPS Width (mm)
438
Rack Height
2U
Shipping Dimensions (hwd / cm)
24.00 x 59.99 x 76.00
Shipping Dimensions (hwd / in.)
9.45 x 23.62 x 29.92
Shipping Weight (kg)
39.46
Shipping Weight (lbs.)
87.00
UPS Housing Material
Steel
UPS Power Module Dimensions (hwd, cm)
8.79 x 43.79 x 61.60
UPS Power Module Dimensions (hwd, in.)
3.46 x 17.24 x 24.25
UPS Power Module Weight (kg)
31.17
UPS Power Module Weight (lbs.)
68.72
Environmental:
Operating Temperature Range
+32 to +104 degrees Fahrenheit / 0 to +40 degrees Celsius.
Storage Temperature Range
+5 to +122 degrees Fahrenheit / -15 to +50 degrees Celsius.
Relative Humidity
5 to 95%, non-condensing
AC Mode BTU / Hr. (Full Load)
531
AC Economy Mode BTU / Hr. (Full Load)
484.5
Battery Mode BTU / Hr. (Full Load)
1037
AC Economy Mode Efficiency Rating (100% Load)
95%
Audible Noise
50 dBA max, front-side @ 1m
Communications:
Network Management Cards
Network Monitoring Port Description
Supports detailed monitoring of UPS and site power conditions; DB9 port supports RS232 and contact closure communications
PowerAlert Software
For local monitoring via the UPS’s built-in communication ports and modify the UPS Power Strategy settings download PowerAlert Local software at [link removed by ]
Communications Cable
USB and DB9 cabling included
WatchDog Compatibility
Supports Watchdog application, OS and hard-reboot restart options for remote applications
Communications Interface
Contact closure; DB9 Serial; EPO (emergency power off); Slot for SNMP/Web interface; USB (HID enabled)