Supports Suite B (one of the strongest cryptographic suites for IPsec) in SummaryInterface slots
8Switch fabric capacity
3.84 TbpsData forwarding capacity
3.2 TbpsPacket routing performance
2.38 billion ppsMaximum 100 GbE ports
16Maximum 40 GbE ports
32Maximum 10 GbE ports
192Maximum 1 GbE ports
384Height (inches/rack units)
12.21 in./7RUSwitch fabric redundancy
1:1Management module redundancy
N+1Power supply redundancy
1+1Airflow
Side to backPowerMaximum DC power consumption (W)
4,060Maximum AC power consumption (W) (100-240 VAC)
4,060Maximum thermal output (BTU/HR)
13,858MechanicalDimensions (WxHxD)17.20 in. X 12.21 in. X 24.0 in.
(43.69 cm X 31.01 cm X 60.96 cm)Weight
171 lb (78 kg)EnvironmentalOperating Temperature0°C to 40°C (32°F to 104°F)Relative Humidity5% to 90%, at 40°C (104°F), non-condensingOperating Altitude6600 ft (2012 m)Storage Temperature−25°C to 70°C (−13°F to 158°F)Storage Humidity95% maximum relative humidity, non-condensingStorage Altitude15,000 ft (4500 m) maximumRegulatory Compliance and Safety ApprovalsSafety Agency Approvals- CAN/CSA-C22.2 No. 60950-1-3
- UL 60950-1
- IEC 60950-1
- EN 60950-1 Safety of Information Technology Equipment
- EN 60825-1 Safety of Laser Products—Part 1: Equipment Classification, Requirements and User\'s Guide
- EN 60825-2 Safety of Laser Product—Part 2: Safety of Optical Fibre Communication Systems
Electromagnetic Emission- ICES-003 Electromagnetic Emission
- FCC Class A
- EN 55022/CISPR-22 Class A/VCCI Class A
- AS/NZS 55022
- EN 61000-3-2 Power Line Harmonics
- EN 61000-3-3 Voltage Fluctuation and Flicker
- EN 61000-6-3 Emission Standard (supersedes EN 50081-1)
Immunity- EN 61000-6-1 Generic Immunity and Susceptibility (supersedes EN 50082-1)
- EN 55024 Immunity Characteristics. Supersedes:
- EN 61000-4-2 ESD
- EN 61000-4-3 Radiated, radio frequency, electromagnetic field
- EN 61000-4-4 Electrical fast transient
- EN 61000-4-5 Surge
- EN 61000-4-6 Conducted disturbances induced by radiofrequency fields
- EN 61000-4-8 Power frequency magnetic field
- EN 61000-4-11 Voltage dips and sags
TELCO NEBS/ETSIDesigned to meet the following specifications (formal testing under way):- Telcordia GR-63-CORE NEBS Requirements: Physical Protection
- Telcordia GR-1089-CORE EMC and Electrical Safety
- Telcordia SR-3580 Level 3
- ETSI ETS 300-019 Physical Protection
— Part 1-1, Class 1.1, Partly Temperature Controlled Storage Locations
— Part 1-2, Class 2.3, Public Transportation
— Part 1-3, Class 3.1, Temperature Controlled Locations (Operational) - ETSI ETS 300-386 EMI/EMC
Power and Grounding- ETS 300 132-1 Equipment Requirements for AC Power Equipment Derived from DC Sources
- ETS 300 132-2 Equipment Requirements for DC Powered Equipment
- ETS 300 253 Facility Requirements
Physical Design and Mounting19-inch rack mount supporting racks compliant with:- ANSI/EIA-310-D
- ETS 300 119
- GR-63-CORE Seismic Zone 4 Table top
Environmental Regulatory Compliance- EU 2002/95/EC RoHS (with lead exemption)
- EU 2002/96/EC WEEE
Network Equipment Building Standards (NEBS)- GR-1089-CORE NEBS EMC and Safety
- GR-63 CORE: NEBS Physical Protection
- SR-3580: NEBS Criteria Levels (Level 3)
Boot Log:NetIron MLX-8 Router#show version
System Mode: MLX
Chassis: MLXe 8-slot (Serial #: BGB2525J00X, Part #: 40-1000362-04)
NI-X-HSF Switch Fabric Module 1 (Serial #: BEU0422J01L, Part #: 60-1001588-14)
FE 1: Type fe600, Version 1
FE 3: Type fe600, Version 1
Switch Fabric Module 1 Up Time is 6 minutes 59 seconds
NI-X-HSF Switch Fabric Module 2 (Serial #: BEU0422J03Y, Part #: 60-1001588-14)
FE 1: Type fe600, Version 1
FE 3: Type fe600, Version 1
Switch Fabric Module 2 Up Time is 6 minutes 59 seconds
SL M1: BR-MLX-MR2-M Management Module Active (Serial #: BVP0414J00R, Part #: 60-1002374-06):
Boot : Version 5.4.0dT165 Copyright (c) 1996-2012 Brocade Communications Systems, Inc.
Compiled on Apr 16 2013 at 11:17:16 labeled as xmprm05400d
(521484 bytes) from boot flash
Monitor : Version 5.4.0dT165 Copyright (c) 1996-2012 Brocade Communications Systems, Inc.
Compiled on Apr 16 2013 at 11:16:38 labeled as xmb05400d
(528036 bytes) from code flash
IronWare : Version 5.4.0dT163 Copyright (c) 1996-2012 Brocade Communications Systems, Inc.
Compiled on Jul 3 2013 at 13:12:20 labeled as xmr05400d
(8879695 bytes) from Primary
Board ID : 00 MBRIDGE Revision : 37
1666 MHz Power PC processor 7448 (version 8004/0202) 166 MHz bus
512 KB Boot Flash (MX29LV040C), 128 MB Code Flash (MT28F256J3)
4096 MB DRAM INSTALLED
4096 MB DRAM ADDRESSABLE
Active Management uptime is 6 minutes 59 seconds
SL M2: BR-MLX-MR2-M Management Module Standby (Serial #: BVP0418J019, Part #: 60-1002374-06):
Boot : Version 5.4.0dT165 Copyright (c) 1996-2012 Brocade Communications Systems, Inc.
Compiled on Apr 16 2013 at 11:17:16 labeled as xmprm05400d
(521484 bytes) from boot flash
Monitor : Version 5.4.0dT165 Copyright (c) 1996-2012 Brocade Communications Systems, Inc.
Compiled on Apr 16 2013 at 11:16:38 labeled as xmb05400d
(528036 bytes) from code flash
IronWare : Version 5.4.0dT163 Copyright (c) 1996-2012 Brocade Communications Systems, Inc.
Compiled on Jul 3 2013 at 13:12:20 labeled as xmr05400d
(8879695 bytes) from Primary
Board ID : 00 MBRIDGE Revision : 37
1666 MHz Power PC processor 7448 (version 8004/0202) 166 MHz bus
512 KB Boot Flash (MX29LV040C), 128 MB Code Flash (MT28F256J3)
4096 MB DRAM INSTALLED
4096 MB DRAM ADDRESSABLE
Standby Management uptime is 6 minutes 21 seconds
SL 1: NI-MLX-10Gx8-M 8-port 10GbE (M) Module (Serial #: BEQ0426J02N, Part #: 60-1001587-16)
(LID: dgsFJHLlFHp)
Boot : Version 5.4.0dT175 Copyright (c) 1996-2012 Brocade Communications Systems, Inc.
Compiled on Apr 16 2013 at 11:17:42 labeled as xmlprm05400d
(520141 bytes) from boot flash
Monitor : Version 5.4.0dT175 Copyright (c) 1996-2012 Brocade Communications Systems, Inc.
Compiled on Apr 16 2013 at 11:18:06 labeled as xmlb05400d
(527544 bytes) from code flash
IronWare : Version 5.4.0dT177 Copyright (c) 1996-2012 Brocade Communications Systems, Inc.
Compiled on Jul 3 2013 at 13:18:48 labeled as xmlp05400d
(7234085 bytes) from Primary
FPGA versions:
Valid PBIF Version = 2.00, Build Time = 3/7/2013 14:03:00
Valid XPP Version = 4.18, Build Time = 2/5/2013 13:32:00
X10G2MAC 0
X10G2MAC 1
X10G2MAC 2
X10G2MAC 3
1333 MHz MPC 8541 (version 8021/0022) 533 MHz bus
512 KB Boot Flash (MX29LV040C), 64 MB Code Flash (MT28F256J3)
1024 MB DRAM, 8 KB SRAM, 286331153 Bytes BRAM
PPCR0: 512K entries CAM, 8192K PRAM, 2048K AGE RAM
PPCR1: 512K entries CAM, 8192K PRAM, 2048K AGE RAM
LP Slot 1 uptime is 6 minutes 19 seconds
All show version done
NetIron MLX-8 Router#show license
Index Package Name Lid Slot License Type Status License Period
1 MLX-1Gx24-X-Upgrade dpcFJGHlFGm normal invalid unlimited
NetIron MLX-8 Router#show chassis
*** MLXe 8-slot Chassis ***
---POWERS ---
Power 1: ( 23-00001 BMG2M12J3XF - AC 1800W): Installed (OK)
Power 2: ( 23-00001 BMG2M12J3TS - AC 1800W): Installed (OK)
Power 3: ( 23-00001 BMG2M17J4JS - AC 1800W): Installed (OK)
Power 4: ( 23-00001 BMG2M17J4JG - AC 1800W): Installed (OK)
Total power budget for chassis = 7200 W
Total power used by system core = 832 W
Total power used by LPs = 406 W
Total power available = 5962 W
Slot Power-On Priority and Power Usage:
Slot1 pri=1 module type=NI-MLX-10Gx8-M 8-port 10GbE (M) Module power usage=246W
Slot3 pri=1 module type=BR-MLX-1GCx24-X 24-port 10/100/1000Base-T Copper Module power usage=160W
--- FANS ---
Back fan A-1: Status = OK, Speed = LOW (50%)
Back fan A-2: Status = OK, Speed = LOW (50%)
Back fan B-1: Status = OK, Speed = LOW (50%)
Back fan B-2: Status = OK, Speed = LOW (50%)
--- TEMPERATURE READINGS ---
Active Mgmt Module: 35.0C 47.875C
Standby Mgmt Module: 36.250C 49.500C
SFM1: FE1:36.500C FE2:36.500C FE3:36.500C
SFM2: FE1:38.125C FE2:38.125C FE3:38.125C
SFM3: not present
LP1 Sensor1: 35.750C
LP1 Sensor2: 41.0C
LP1 Sensor3: UNUSED
LP1 Sensor4: 34.125C
LP1 Sensor5: 45.625C
LP1 Sensor6: UNUSED
LP1 Sensor7: UNUSED
Fans are in auto mode (current speed is LOW (50%)). Temperature monitoring poll period is 60 seconds.
--- MISC INFO ---
Backplane EEPROM MAC Address: cc4e.2418.5d00
NetIron MLX-8 Router#show module
Module Status Ports Starting MAC
M1 (left ):BR-MLX-MR2-M Management Module Active
M2 (right):BR-MLX-MR2-M Management Module Standby(Ready State)
F1: NI-X-HSF Switch Fabric Module Active
F2: NI-X-HSF Switch Fabric Module Active
F3:
S1: NI-MLX-10Gx8-M 8-port 10GbE (M) Module CARD_STATE_UP 8 cc4e.2418.5d00
S2:
S3: BR-MLX-1GCx24-X 24-port 10/100/1000Base-T Copper Module CARD_STATE_INTERACTIVE 0 cc4e.2418.5d60
(S3: Configured as invalid module)
S4:
S5:
S6:
S7:
S8:
NetIron MLX-8 Router#
CS 205337 205336 dup .co.uk
![Buy Now Buy Now](buy.gif)